12Call a proDifficulty: Hard

Safety first: this problem can involve gas, refrigerant or high voltage. Use this guide to understand the issue, and have a licensed technician do any repair inside the appliance.

Rinnai Code 12: Flame Failure, Causes and Safe Checks

Illustration of a white wall-mounted tankless water heater with a gray vent pipe on top, a flame icon on its left and an orange warning triangle on its right, on a mint green background.

Quick Answer

Rinnai code 12 means Flame Failure: the tankless heater shut down because its burner flame failed. Rinnai's guide ties it to gas supply or pressure, vent or air problems, a loose flame rod or sparker, wiring and grounding. Check that the gas valve is open and the outdoor vent is clear, then call a licensed gas technician if the code returns.

On this page
  1. What does Rinnai code 12 mean?
  2. What causes Rinnai code 12?
  3. What can you safely check yourself?
  4. What should you do if you smell gas or a CO alarm sounds?
  5. When should you call a technician?
  6. How can you keep code 12 from coming back?
  7. Frequently Asked Questions
  8. Our Take
  9. Sources

Key Takeaways

  • Rinnai titles code 12 "Flame Failure" for its SENSEI, SENSEI RX/CX and Non-SENSEI tankless series; the heater shuts down when the burner flame is extinguished.
  • Rinnai's causes include gas supply and pressure, venting, a loose flame rod or sparker, fan debris, damp wiring and grounding.
  • Safe owner checks stay outside the cabinet: the gas valve, the propane tank, the outdoor vent and one power cycle.
  • If you smell gas, leave the home and call the gas utility from outside; if a CO alarm sounds, get outside and call 911.
  • Rinnai says only trained, qualified professionals should follow its diagnostic steps, and never to adjust the internal gas valve.

What does Rinnai code 12 mean?

Rinnai's own diagnostic guide titles code 12 "Flame Failure" and lists it for its SENSEI, SENSEI RX/CX and Non-SENSEI series [1]. That guide covers Rinnai's gas tankless models, including the RU, RX, RE, V and R-LS lines and the RH180 hybrid, so this page is about those units. We found no code 12 meaning for other Rinnai product types, so we do not cover them. Everything here comes from manufacturer and government pages, in line with our editorial policy, and the HomeFixCodes team did not test any repair on a real heater.

Code 12 means the heater shut itself off because its burner flame failed. An older Rinnai VA Series manual lists the same "12 Flame Failure" entry and describes the safety feature behind it: the appliance shuts down automatically if the burner flame is extinguished [2]. The same manual explains that ignition is electronic, with no pilot light, and that the burner lights when a hot water tap opens and goes out when it closes [2].

Where code 12 fits in a Rinnai heating cycleFour steps. A hot tap opens and the burner lights automatically. The fan starts and the sparker fires; failure here is code 11, No Ignition. The flame lights and must stay lit. If the flame fails, the heater shuts down and shows code 12, Flame Failure. 1A hot tap opensThe burner lights automatically 2Fan runs, sparker firesNo ignition here shows code 11 3Flame lights and must stay litThe flame rod senses the flame 4Flame fails: heater shuts downThe display shows code 12, Flame Failure Rinnai: the appliance shuts down if the burner flame is extinguished.
Where code 12 fits in a Rinnai heating cycle, based on Rinnai's guide and VA manual.

Rinnai lists code 12 next to two neighbors that sound alike but point at different problems:

CodeRinnai's titleApplies to
10Air Supply, Exhaust Blockage or Condensate Trap is FullSee Rinnai's guide for the series split [1]
11No IgnitionSENSEI, SENSEI RX/CX, Non-SENSEI [1]
12Flame FailureSENSEI, SENSEI RX/CX, Non-SENSEI [1]

If you are not sure which brand or series your code belongs to, check it in our error code lookup. Rinnai's code meanings are model specific, so match the code to your heater's rating plate before you act on any advice you find online.

What causes Rinnai code 12?

Rinnai does not name one cause. Its code 12 section lists many, and most sit inside the cabinet or in the gas and vent system. Several of them involve gas pressure, venting or electrical faults that a homeowner cannot test safely.

Where a Rinnai flame failure can startSimplified side view of a gas tankless water heater with five numbered areas: 1 gas supply, 2 vent and air intake, 3 fan and burner, 4 flame rod and sparker, 5 wiring and grounding. Areas 1 and 2 have parts a homeowner can look at from outside; areas 3, 4 and 5 are professional work. Gas in Vent out 1 2 3 4 5 1Gas supplyValve open, propane tank not empty. Pressure is pro work. 2Vent and air intakeLook from the ground. Joints and length are pro work. 3Fan and burnerDebris, insects, burner condition: pro work. 4Flame rod and sparkerLoose, dirty or damaged parts: pro work. 5Wiring and groundingDamp connections, grounding, shorts: pro work. Teal = you can look. Amber = licensed technician only.
Five areas where Rinnai's guide says a flame failure can start, and which ones an owner can look at.
AreaWhat Rinnai's guide saysWho should check it
Gas supplyMake sure gas is on at the water heater, gas meter or propane tank, and that a propane tank has gas [1]You can look at the valve and tank; pressure checks are for a gas technician
Gas pressureThe minimum listed inlet pressure must be kept with every gas water heater at the site firing on high; a properly sized system should lose no more than 0.3 in. w.c. on natural gas or 0.5 in. w.c. on propane [1]Licensed gas technician
Venting and airLoose joints, wrong fittings or poor terminal clearances can recirculate combustion gases, cause incomplete combustion and trigger code 12 [1]Technician (you can look at the outdoor terminal)
Flame rod and sparkerBoth must be tight in their bracket; loose parts are removed, cleaned or replaced; a cracked silicone sleeve can also lead to code 12 [1]Qualified technician
FanDebris or insects on the fan wheel or in the burner area are a listed cause [1]Qualified technician
Wiring and groundingDamp connections can short and cause code 12; a properly grounded circuit is critical [1]Technician or licensed electrician
Gas valveCondensate, debris or a malfunctioning part inside the gas valve may keep it from operating [1]Technician

A code that shows up the moment hot water starts is a special case. For SENSEI-series models Rinnai says an immediate code 12 with no flame visible in the burner box points to an electrical short in a wiring harness, a water flow control, a bypass valve or another part of the DC circuit [1]. Finding the short means unplugging components one at a time, which is not a homeowner job.

The pressure numbers matter for one reason: gas demand adds up. Rinnai's test is run with all gas water heaters at the location firing at once [1], so a heater can work alone and fail when a second large appliance is also running. In our reading, that is why a gas technician measures pressure under load rather than guessing.

What can you safely check yourself?

Rinnai states that only trained and qualified professionals are permitted to follow the instructions in its diagnostic guide, and its code 12 section warns that you must be qualified to service gas systems [1]. So our list stops at the outside of the heater. Do not open the cabinet, remove burners or adjust any gas part.

Safe checks for Rinnai code 12Decision chart. Step 1: if you smell gas or a CO alarm sounds, leave and call the gas utility or 911 from outside. Step 2: confirm the gas valve is open and the propane tank is not empty. Step 3: check the outdoor vent is clear of snow, ice and debris. Step 4: turn power off and on once; if code 12 returns, stop and call a licensed gas technician or Rinnai. Code 12 on the display 1. Smell gas, or a CO alarmsounding? Yes Leave now. Callgas utility or 911from outside No 2. Gas valve open? Propanetank not empty? No Open the valve orrefill the tank,then retry once Yes 3. Outdoor vent clear of snow,ice and debris? No Clear what you canreach from theground, then retry Yes 4. Power off, then on once.Does code 12 return? No Run hot water andwatch for repeats.Book a service check Yes Stop. Call a licensed gastechnician or Rinnai. Never open the cabinet or adjust gas parts. Rinnai: only trained professionals follow its guide.
The short list of safe owner checks for Rinnai code 12, all outside the cabinet.
  1. Smell for gas first. If you smell gas, do not do anything else on this list (see the next section).
  2. Look at the gas supply. Rinnai's first listed step is to make sure the gas is on at the water heater, the gas meter or the propane tank, and that a propane tank is not empty [1]. Use the valve's own open marking or your manual to confirm it is fully open.
  3. Look at the outdoor vent terminal. From the ground, check that nothing blocks the air intake or exhaust. Rinnai says to keep the area around the flue terminal free of snow and ice, because the appliance will not work properly if the intake or exhaust is blocked [2]. Do not climb up or take the vent apart.
  4. Turn the power off and on once. In our view this is a reasonable low-risk test, but Rinnai's code 12 section does not list a reset step, so treat it as a test, not a fix. Run a hot tap and watch whether the code returns.
  5. Write down the model number and the code from the display or rating plate. Rinnai asks you to identify the code when you call for service [2].

Some steps you may see online are not safe for owners. Rinnai says not to adjust the internal gas valve because no adjustment is needed, and that doing so voids the warranty. It also says not to run the heater without the front panel installed, and that any alteration to the heater or its controls can be dangerous [1].

What should you do if you smell gas or a CO alarm sounds?

Stop troubleshooting. Rinnai's safety instructions say to smell all around the heater area, including near the floor because some gas settles low. If you smell gas, do not try to light any water heater, do not touch an electrical switch and do not use a phone in the building. Call your gas supplier from a neighbor's phone and follow its instructions, or call the fire department if you cannot reach it [1]. In plain terms: if you smell gas, leave the home and call the gas utility from outside.

Carbon monoxide gives no smell warning. The U.S. Consumer Product Safety Commission advises CO alarms on every level of the home and outside sleeping areas, and says that if an alarm sounds you should get outside to fresh air immediately and call 911 [3]. CPSC lists headache, dizziness, weakness, nausea, vomiting, sleepiness and confusion as symptoms [3]. Do not restart a heater that was running when a CO alarm went off until a technician has inspected it.

When should you call a technician?

Call a licensed gas technician or plumber, or Rinnai, if code 12 returns after your outdoor checks and one power cycle. Also call if the code shows up immediately each time hot water starts, or if you are not sure which checks above apply to your model. The older VA manual says to call a service technician for any remedy that involves gas or electricity [2].

Expect the technician to work through the same list Rinnai publishes: inlet gas pressure with every appliance firing, vent joints and clearances, the flame rod and sparker (Rinnai gives an electrode gap of 0.138 in., or 3.5 mm), the wiring harness, grounding, the fan and the gas valve [1]. Give them the code, the model number and when it happens (first start of the day, only with other gas appliances running, or every time). Those details narrow the search quickly.

Browse our Rinnai guides or the wider set of water heater guides while you wait.

How can you keep code 12 from coming back?

Because the causes sit in the gas, vent and electrical systems, prevention is mostly upkeep by a professional.

  • Schedule an annual inspection. The VA manual says a qualified service technician should inspect the appliance annually and that the vent system should be inspected at least annually for blockages or damage [2].
  • Keep the vent terminal clear. Remove snow and ice that you can reach safely from the ground [2].
  • Keep flammables away. Rinnai says to keep the area around the heater free of gasoline, cleaning solvents, aerosols and other flammable liquids and vapors [1].
  • Recheck gas capacity when you add appliances. In our reading, a new gas range, furnace or second heater can lower the pressure the first one sees, so ask the installer to confirm the gas line is sized for the total load.

Frequently Asked Questions

Is Rinnai code 11 the same as code 12?

No. Rinnai lists code 11 as No Ignition and code 12 as Flame Failure, and each has its own troubleshooting section. Both involve the burner, so the same technician visit can cover them, but the checks differ.

Can I keep using my Rinnai heater if code 12 only appears sometimes?

In our view, an occasional code 12 is still a reason to book a service check, because the cause may be gas pressure, venting or wiring that gets worse over time. If you ever smell gas or a CO alarm sounds, stop using the heater and follow the safety steps above.

Will turning the power off and on clear code 12?

It might clear a one-time fault, but Rinnai's code 12 section does not list a reset as the fix. Treat one power cycle as a test. If the code comes back, the heater is telling you something is wrong with the gas, vent, flame sensing or wiring.

Our Take

We think code 12 is a good example of an error that looks like a simple reset but usually is not. Rinnai's own guide lists causes that run from a closed gas valve to gas pressure under load, vent recirculation, a loose flame rod and a short in the wiring, and most of those need gas or electrical training. In our view the sensible owner move is short: confirm the gas is on, glance at the outdoor vent, try one power cycle and write down the model and code. Past that point we would book a licensed gas technician rather than open the cabinet. Smell gas or hear a CO alarm, and we would leave the home before doing anything else. These opinions are based on Rinnai's published guidance, not on our own repairs.

Sources

  1. Troubleshooting Tankless Water Heater Diagnostic Codes. Rinnai America Corporation.
  2. VA Series Indoor LS Manual (Owner's Operation and Installation). Rinnai America Corporation.
  3. Carbon Monoxide Information Center. U.S. Consumer Product Safety Commission, n.d..

Repair information is general guidance. Unplug the appliance and shut off water or gas before working on it, follow your owner's manual, and call a qualified technician for gas, refrigerant or high-voltage work. Spotted an error? Tell us.