Prefer a technician? Find a Rheem Pro(official Rheem site)
Rheem Tankless Code 11: Ignition Failure Explained

Quick Answer
Code 11 on a Rheem gas tankless water heater means the burner tried to light and no flame was detected. Rheem's owner chart points first to a gas shut-off valve that is not fully open, so open it completely and reset the heater. If 11 comes back, turn the heater off and call a licensed gas technician. If you smell gas, leave the home and call the gas utility from outside.
On this page
- What does Rheem tankless code 11 mean?
- What causes code 11 on a Rheem tankless heater?
- What can you safely check yourself?
- What should you leave to a technician?
- How is code 11 different from code 12 and other Rheem codes?
- What should you tell the service company, and will it need a new heater?
- Frequently Asked Questions
- Our Take
- Sources
Key Takeaways
- Code 11 is an ignition fault: Rheem's technician manual says the heater tries to light 2 times and shows 11 if no flame is detected.
- Rheem's homeowner chart lists a gas shut-off valve that is not fully open as the first thing to check, and says to open it completely.
- Safe owner steps are limited to the valve, Rheem's power reset, other gas supplies and a look at the outdoor vent; gas filters, igniters, flame rods and gas valves are technician work.
- If you smell gas, leave the home and call the gas utility from outside; if 11 returns after a reset, call a licensed gas technician.
What does Rheem tankless code 11 mean?
Code 11 is an ignition error. On a Rheem gas tankless water heater, code 11 means the unit tried to light its burner and the flame rod never detected a flame. Rheem's technician manual says the heater tries to ignite 2 times, and if no flame is detected it shows "11" on the built-in or remote controller [1].
Rheem's homeowner manuals describe the same code from the supply side. Their error chart lists 11 as "The gas shut-off valve is not fully opened," and the fix is to check the shut-off valve and open it completely [2]. The condensing models' manual carries the same entry [3]. So the first thing to rule out is a gas valve that is not fully open, even though the technician manual lists more causes.
Which models does this cover? Rheem's technician manual for its "-3" series lists both condensing RTGH models (for example RTGH-84DVLN-3 and RTGH-95DVELN-3) and non-condensing RTG and ECO models (for example RTG-84XLN-3 and ECO160DVLN-3) [1]. The homeowner manuals we used cover non-condensing 160,000 to 199,900 Btu/h models [2], non-condensing models with built-in recirculation [4] and condensing models [3]. Your model and serial number are on the rating plate on the side of the heater [2].
Not every Rheem uses a plain "11." Rheem's IKONIC S and SR series show the same fault as A011, and that pocket guide says the heater makes up to 10 ignition attempts before showing it [5]. This guide is about gas models, because only a burner can fail to ignite. The same number can mean something else on other brands, so check your own brand in our error code lookup.
What causes code 11 on a Rheem tankless heater?
Rheem's technician manual lists five diagnostic check items for code 11: gas supply pressure, the gas filter, venting, the igniter rod and the flame rod [1]. The table below turns them into plain terms and shows who should handle each one.
| Cause | What Rheem says | Who handles it |
|---|---|---|
| Gas valve not fully open | The homeowner chart lists this first; open the valve completely [2] | You |
| Gas supply problem | Supply pressure is measured at the heater's gas connection. Natural gas should read 4.0 to 10.5 inches W.C. and propane 8.0 to 13.0 [1]. The chart also lists interrupted gas service and a low propane supply [2] | Gas utility, propane supplier or technician |
| Blocked gas filter | A filter at the gas connection can be blocked by foreign matter and must be cleaned [1] | Technician |
| Venting problem | Disconnected vent pipes or a blocked vent termination, on the inlet or exhaust side [1] | You can look from outside; technician for any pipework |
| Wrong DIP switch settings | Switches must match the venting and altitude [1] | Technician |
| Igniter or flame rod | If there is no spark, the igniter rod and coil are tested; if the flame is not sensed, the flame rod is checked [1] | Technician |
| Gas valve or control board | The flowcharts end with replacing these if the tests fail [1] | Technician |
One detail explains why a heater can fail only some of the time. Rheem notes that the gas pressure can look normal while the heater is idle (static pressure), yet drop when it runs at full output or when another gas appliance is in use (dynamic pressure), so technicians check both [1]. A code 11 that appears only on busy mornings points to supply, not to a bad part.
What can you safely check yourself?
Work through these checks in order. Rheem's own owner steps are short, and everything past them is technician work.
- Smell gas? Leave first. Rheem's manual says not to try to light any appliance, not to touch any electrical switch or use a phone in the building, and to call your gas supplier from a neighbor's phone. If you cannot reach the supplier, call the fire department, and do not return until the supplier or fire department says it is safe [2]. If you smell gas at any point, leave the home and call the gas utility from outside.
- Open the gas shut-off valve all the way. This is Rheem's listed fix for code 11 [2]. If the valve will not move easily, stop and call a pro rather than forcing it.
- Reset the heater the way Rheem describes. Turn off all hot water faucets, then turn the heater off with the POWER ON/OFF button on the controller. Wait about 5 minutes, turn it back on, and open a hot water faucet to see whether the code returns. If it is still showing, turn off the faucet and the heater, unplug it, wait about 30 seconds, plug it back in, and recheck [2].
- Check the other gas supplies. If your range or furnace also acts up, the chart tells you to contact your gas utility when gas service has been interrupted. On a propane model, it says to refill or replace the LP container when the supply is low [2].
- Look at the vent outside, from the ground. For its venting codes, Rheem says to remove any blockage at the air intake or vent exhaust and to keep 12 inches of clearance around the air intake [2]. Brush away loose leaves or debris you can reach safely. Do not take vent pipes apart.
If code 11 returns after a fully open valve and a reset, stop and call a licensed gas technician. Rheem's instruction is to turn off the faucet and the heater, note the displayed code, and call for service [2].
What should you leave to a technician?
Almost everything else. Rheem's owner manual warns, "DO NOT attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors, or other safety devices," and tells you to refer repairs to a qualified service technician [2]. The troubleshooting manual itself says it is for technicians and service professionals only, and sends homeowners to the Use and Care manual [1].
That means no opening the cabinet to clean the igniter or flame rod, no cleaning the gas filter, no adjusting gas pressure, and no bypassing or jumping any sensor to make the heater fire. Rheem's flowcharts show why. A dirty igniter rod or flame rod sometimes just needs cleaning, but the same chart can end at a new igniter coil and rod, flame rod, gas valve or control board, and telling them apart takes meters and training [1].
A failing burner or vent is also a good reason to check your carbon monoxide alarms. The U.S. Consumer Product Safety Commission says to install battery-operated CO alarms, or CO alarms with battery backup, on every level of the home and outside sleeping areas [6].
How is code 11 different from code 12 and other Rheem codes?
Several Rheem codes sound alike, and they send you in different directions. Code 12 is the closest relative: the heater saw a flame and then lost it.
| Code | Rheem's meaning | What the homeowner chart says to do |
|---|---|---|
| 11 | Flame not detected after ignition attempts [1] | Open the gas shut-off valve completely [2] |
| 12 | Flame detected, then lost; shown after 3 consecutive incidents [1] | Contact the gas utility if service was interrupted; refill propane if low [2] |
| 90 or 99 | Blockage detected in the venting [1] | Remove any blockage; the air intake needs 12 inches of clearance [2] |
| P1 | Not enough water flow to run the unit [2] | Increase the flow from the fixtures [2] |
| 1L | Lime buildup in the water heater [2] | Contact a dealer or qualified service technician [2] |
If the code on your screen is not in the chart, Rheem says to turn the heater off immediately and call for service [2].
What should you tell the service company, and will it need a new heater?
Rheem's flowcharts for code 11 end at part replacements, not at replacing the whole heater [1]. In our reading, a closed valve or a gas supply problem is the best case, and a failed igniter, flame rod, gas valve or board is a repair a technician can price after testing. We do not quote prices here because they vary by model and region.
Have these ready when you call, as Rheem's manual asks: the model and serial number, the address, the installer's name, the original installation date, any past service dates, and details of the problem [2]. Tell them the exact code, that you opened the gas valve fully, and that you tried the reset. You can also browse our pages on water heater error codes and problems and Rheem appliances. For how we handle safety topics, see our editorial policy and about page.
Frequently Asked Questions
Can I keep using my Rheem tankless heater if code 11 keeps returning?
Not by repeating resets. Rheem's instruction is that if the code is still shown after the owner steps, you turn off the hot water faucet and the heater, note the displayed code and call for service [2]. If you ever smell gas, leave the home and call the gas utility from outside.
Does code 11 mean my home has no gas?
Not always. Code 11 means no flame was detected after the ignition attempts [1]. A closed gas valve, interrupted gas service or low propane are on Rheem's owner chart [2], but a blocked gas filter, vent problem, dirty or failed igniter or flame rod, gas valve or control board can produce the same code [1].
Why does my Rheem show A011 instead of 11?
Rheem's IKONIC S and SR series use A011 for the same fault, flame not detected by the flame rod. Its pocket guide says the heater makes up to 10 ignition attempts before it shows the code [5].
Is Rheem code 11 the same as code 12?
No. Code 11 means no flame was ever detected. Code 12 means the heater detected a flame and then lost it, and it is shown after 3 consecutive incidents [1].
Our Take
We think code 11 is a good example of a fault that looks alarming but starts with a free check. Rheem's own owner chart puts the gas shut-off valve first, and in our view that is where a homeowner should stop and hand over to a pro. The technician manual shows why: the same code can come from low gas pressure, a blocked gas filter, a vent problem, a dirty igniter or flame rod, or a failed gas valve or control board, and none of those are safe to guess at. We would not open the cabinet to clean parts, and we would never look for a way to bypass a sensor. Open the valve, reset once, and if 11 comes back, call a licensed technician.
Sources
- High and Super High Efficiency Tankless Water Heater Troubleshooting Manual (AP21822 Rev 02). Rheem Manufacturing Company, 2025.
- High-Efficiency Non-Condensing Tankless Water Heater Use and Care Manual (AP22009 Rev 04). Rheem Manufacturing Company, n.d..
- Super High Efficiency Condensing Tankless Water Heater Use and Care Manual (AP21820 Rev 06). Rheem Manufacturing Company, n.d..
- High-Efficiency Non-Condensing Tankless Water Heater with Recirculation Use and Care Manual (AP23962 Rev 02). Rheem Manufacturing Company, n.d..
- Technical Training and Service Manual Pocket Guide: Tankless Water Heaters, IKONIC S and SR series (AP24727). Rheem Manufacturing Company, n.d..
- Carbon Monoxide Information Center. U.S. Consumer Product Safety Commission, n.d..
Repair information is general guidance. Unplug the appliance and shut off water or gas before working on it, follow your owner's manual, and call a qualified technician for gas, refrigerant or high-voltage work. Spotted an error? Tell us.